With Remmon’s Serial over IP solutions, you only need basic Internet connection (no static IP) and our R-PIPE unit to easily transfer data from one side of the globe to the other side. By using the regular cellular network, you can connect to remote devices without any distance limitation.
Remmon server-based Serial over IP technology consists of the R-PIPE (attached to PLC device), Internet server running Remmon application software and a computer with Internet communication running Remmon Cell-PIPE application software.
Serial over IP technology is based on three major components:
The Cell-Pipe software application is installed on the client’s computer and creates a virtual com (e.g. com 37), creating a wireless link between the end unit and the com for serial communication. The client’s software can use virtual com as a standard management system. On the other side, Cell-PIPE establishes TCP/IP communication (over the Internet) with Remmon’s server for full data transformation.
The R-PIPE contacts the local device to receive and transfer data using RS232/485 connections. At the same time, the R-PIPE creates a TCP/IP connection (with the GSM/GPRS cellular network) with the Remmon server that enables the data transformation.
Remmon’s server connects between the cell pipe software and the R-PIPE on the field for data transformation. The server can be easily managed via easy-to-use Web-based management software. Using a Web browser, you can login to the server, and monitor, configure and manage all of your connections.
The R-PIPE is an easy-to-use, lightweight and compact GSM/GPRS cable that is both versatile and easy to operate.
Technical Specifications
|
HW interfaces
|
|
RS-232/485
|
One DB9 male (standard EIA)
|
|
Display
|
2 Leds (red, yellow)
|
|
Physical Characteristic
|
|
Dimension
|
104 X 67 X 33 cm
|
|
Weight
|
200 gram
|
|
Assembly
|
2 screw handles
|
|
Power supply Specification
|
|
Power supply
|
9-24VDC 1A
|
|
Active current
|
100mA
|
|
Stand by current
|
30mA
|
|
Protection
|
According to MIL-STD-704E
|
|
Environment
|
|
Operating Temperature
|
-200C to 700C
|
|
Storage Temperature
|
-400C to 850C
|
|
Operating Humidity
|
5% to 95%
|
|
Transferring Data
|
|
Socket definition
|
Compatible for DNS definition
|
|
Packet Time-out
|
Minimum 100ms
|
|
TCP Time-out
|
Minimum 1 minute before disconnecting
|
|
Reconnect interval
|
Minimum 30 sec
|
|
Cellular Network Interface
|
|
Band
|
Quad band
|
|
Protocols
|
GPRS class 10, Mobile station class B
|
|
Internal modem
|
Telit 864
|
|
Modem Approvals
|
Fully type approved according to R&TTE
CE, GCF, FCC, PCTRB, IC
|
|
Technology
|
GSM network + SIM card
|
|
Antenna
|
Internal antenna MMCX
External antenna MMCX
|
|